Drive shafts and pulleys
250(1)An employer shall ensure that exposed parts of permanently installed horizontal shafting within 2.1 m of a floor, walkway or work area are guarded with
(a) casings completely enclosing the shafting,
(b) casings in the form of a trough enclosing either the top and both sides or the bottom and both sides of the shafting as the location requires, or
(c) railings that are placed not less than 300 mm nor more than 500 mm from any moving part.
250(2)An employer shall ensure that exposed parts of permanently installed vertical shafting within 2.1 m of a floor, walkway or work area are enclosed with stationary casings.