Portable power-operated hand tools
83An employer shall ensure that
(a)
a portable power-operated hand tool is cleaned with a nonflammable, non-toxic solvent or according to the manufacturer’s specifications,
(b)
an electric portable power-operated hand tool is double insulated or bonded to ground or, if it is not double insulated and it is not practical to bond to ground, is equipped with a double insulated portable ground fault circuit interrupter of the class A type,
(c)
fittings and couplings appropriate for the intended use and meeting the manufacturer’s specifications are used on all hydraulic, pneumatic, chemical and electrical lines and hoses for a portable power-operated hand tool, and
(d)
a shut-off that is readily accessible to the user of the tool is installed on all hydraulic, pneumatic, chemical and electrical lines and hoses for a portable power-operated hand tool.