Column 1 Prescribed Product | Column 2 Standard | Column 3 Energy Performance Standard | Column 4 Prescribed Date |
1 Household electric ranges that are (a) free-standing ranges equipped with surface elements and one or more ovens, (b) built-in combinations of surface elements and one or more ovens, (c) wall-mounted ovens with one or more ovens, or (d) counter-mounted surface element assemblies | CAN/CSA-C358-M89 Energy Consumption Test Methods for Household Electric Ranges | Ranges: E is equal or less than 0.93 V + 14.3 Cooktops - conventional, solid or smooth: E is equal or less than 34 Cooktops - modular type: E is equal or less than 43 Wall mounted ovens: E is equal or less than 38 | June 1, 1995 June 1, 1995 June 1, 1995 June 1, 1995 |
1.1 Household electric ranges that are free-standing or built-in appliances with one or more surface elements and one or more ovens | CSA C358-03 Energy Consumption Test Methods for Household Electric Ranges | Clause 8(a) of CSA-C358-03 | August 31, 2004 |
1.2 Household electric ranges that are counter-mounted appliances without ovens and with one or more surface elements | CSA C358-03 Energy Consumption Test Methods for Household Electric Ranges | Clause 8(b) of CSA-C358-03 | August 31, 2004 |
1.3 Household electric ranges that are built-in or wall-mounted appliances with one or more ovens and no surface elements | CSA C358-03 Energy Consumption Test Methods for Household Electric Ranges | Clause 8(c) of CSA-C358-03 | August 31, 2004 |
2 Standard or compact household electric automatic clothes washers that are top-loaded or front-loaded (other than wringer washers, twin tub washer and spinners and front loading water heating washers) | CAN/CSA-C360-92 Test Method for Measuring Energy Consumption and Capacity of Automatic Household Clothes Washers | Clause 8.4 of CAN/CSA-C360-92 | June 1, 1995 |
CSA C360-03 Energy Performance, Water Consumption, and Capacity of Household Clothes Washers | Table 9 of CSA C360-03 | August 31, 2004 |
CAN/CSA-C360-03 Energy Performance, Water Consumption, and Capacity of Household Clothes Washers | Table 10 of CAN/CSA-C360-03 | December 31, 2006 |
CAN/CSA-C360-03 Energy Performance, Water Consumption, and Capacity of Household Clothes Washers (as reaffirmed in 2009) | Clause 8.5.3 and Table 11 of CAN/CSA-C360-03 (as reaffirmed in 2009) | June 1, 2012 |
3 Standard or compact electrically operated and heated household tumble-type clothes dryers | CAN/CSA-C361-92 Test Method for Measuring Energy Consumption and Drum Volume of Electrically Heated Household Tumble-Type Clothes Dryers | Clause 8.3 of CAN/CSA-C361-92 | June 1, 1995 |
4 Electrically operated automatic dishwashers that are not commercial, industrial or institutional machines | CAN/CSA-C373-92 Energy Consumption Test Methods for Household Dishwashers | Clause 7.4 of CAN/CSA-C373-92 | June 1, 1995 |
CAN/CSA-C373-04 Energy consumption test methods and limits for household dishwashers | Compact Dishwashers: Clause 10.2 and Table 2 of CAN/CSA-C373-04 | June 1, 2012 |
Standard Dishwashers: Clause 10.3 and Table 3 of CAN/CSA-C373-04 | June 1, 2012 |
5 Stationary electric storage tank water heaters with a capacity of between 50 l and 450 l inclusive that are intended for use on pressure systems | CAN/CSA-C191.1-M90 Performance Options for Electric Storage Tank Water Heaters | Clause 5.1 of CAN/CSA-C191.1-M90 | June 1, 1995 |
CSA C191-00 Performance of Electric Storage Tank Water Heaters for Household Service | Maximum standby loss in W = (a) for tanks with a bottom inlet (i) 40 + 0.2 V for tanks with V ≥ 50 l and ≤ 270 l, and (ii) 0.472 V − 33.5 for tanks with V > 270 l and ≤ 454 l (b) for tanks with top inlet (i) 35 + 0.2 V for tanks with V ≥ 50 l and ≤ 270 l, and (ii) 0.472 V − 33.5 for tanks with V > 270 l and ≤ 454 l | August 31, 2004 |
5.1 Electric storage tank water heaters and heat pump water heaters with a capacity of between 76 l and 454 l | CAN/CSA-C191-04 Performance of electric storage tank water heaters for domestic hot water service | Maximum standby loss in W for top-fill tanks of (a) ≤ 25 + (0.20 × V) for 50 l to 270 l tanks, and (b) ≤ (0.472 × V) - 48.5 for 270 l to 454 l tanks | June 1, 2012 |
CAN/CSA-C745-03 Energy Efficiency of Electric Storage Tank Water Heaters and Heat Pump Water Heaters | Clause 9 - Energy Factor, CAN/CSA- C745-03 | June 1, 2012 |
6 Refrigerators or combination refrigerator-freezers and freezers | CAN/CSA-C300-M91 Capacity Measurement and Energy Consumption Test Methods for Refrigerators, Combination Refrigerator-Freezers, and Freezers | Column 4 of Table 9.1 of CAN/ CSA-C300-M91 | June 1, 1995 |
6.1 Refrigerators or combination refrigerator-freezers with a total refrigerated volume ≥ 410.65 l and ≤ 521.10 l | CAN/CSA-C300-00 Energy Performance and Capacity of Household Refrigerators, Refrigerator-Freezers and Freezers | Column B of Table 1 of CAN/CSA-C300-00 | August 31, 2004 |
6.2 Freezers | CAN/CSA-C300-00 Energy Performance and Capacity of Household Refrigerators, Refrigerator-Freezers and Freezers | Column B of Table 1 of CAN/CSA-C300-00 | August 31, 2004 |
6.3 Household refrigerators, refrigerator-freezers and wine chillers other than refrigerators employing an absorption refrigeration system | CAN/CSA-C300-08 Energy performance and capacity of household refrigerators, refrigerator-freezers, freezers, and wine chillers | Third column of Table 1 of CAN/CSA-C300-08 | June 1, 2012 |
7.1 Gas furnaces with an input rate not greater than 65.92 kW (225,000 BTU/h) that use single-phase electric current | ANSI Z21.47-2003/CSA 2.3-2003 Gas-Fired Central Furnaces | Annual fuel utilization efficiency ≥ 78% | August 31, 2004 |
7.2 Gas furnaces with an input rate not greater than 65.92 kW (225,000 BTU/h) that use three-phase electric current | ANSI Z21.47-2003/CSA 2.3-2003 Gas-Fired Central Furnaces | Annual fuel utilization efficiency ≥ 78% or thermal efficiency ≥ 80% | August 31, 2004 |
7.3 Gas furnaces with an input rate greater than 65.92 kW (225,000 BTU/h) but not greater than 117.23 kW (400,000 BTU/h) | ANSI Z21.47-2003/CSA 2.3-2003 Gas-Fired Central Furnaces | Thermal efficiency ≥ 80% | August 31, 2004 |
7.4 Gas furnaces with an input rate not greater than 65.92 kW (225,000 BTU/h) except those with cooling units or those that are outdoor, through-the-wall or used in mobile homes or recreational vehicles | CAN/CSA-P.2-07 Testing method for measuring the annual fuel utilization efficiency of residential gas-fired furnaces and boilers | Annual fuel utilization efficiency ≥ 90% | June 1, 2012 |
7.5 Outdoor gas furnaces that have an integrated cooling component, an input rate not greater than 65.92 kW (225,000 BTU/h) and use single-phase electric current | CAN/CSA-P.2-07 Testing method for measuring the annual fuel utilization efficiency of residential gas-fired furnaces and boilers | Annual fuel utilization efficiency ≥ 78% | June 1, 2012 |
7.6 Gas furnaces that are through-the-wall, have an integrated cooling unit, an input rate not greater than 65.92 kW (225,000 BTU/h) and use single-phase electric current | CAN/CSA-P.2-07 Testing method for measuring the annual fuel utilization efficiency of residential gas-fired furnaces and boilers | Annual fuel utilization efficiency ≥ 78% | June 1, 2012 |
CAN/CSA-P.2-07 Testing method for measuring the annual fuel utilization efficiency of residential gas-fired furnaces and boilers | Annual fuel utilization efficiency ≥ 90% | December 31, 2012 |
7.7 Gas-fired, warm-air industrial or commercial package furnace that has an input rate greater than 65.92 kW (225,000 BTU/h) and uses single-phase electric current | CAN/CSA-P.8-09 Thermal efficiencies of industrial and commercial gas-fired package furnaces | Clause 4, CAN/CSA-P.8-09 | June 1, 2012 |
7.8 Gas-fired, warm-air industrial or commercial package furnace that has an input rate not greater than 2 931 kW (10,000,000 BTU/h) and uses three-phase electric current | CAN/CSA-P.8-09 Thermal efficiencies of industrial and commercial gas-fired package furnaces | Clause 4, CAN/CSA-P.8-09 | June 1, 2012 |
7.9 Gas-fired unit heaters with an input rate not greater than 2 931 kW (10,000,000 BTU/h) | CAN/CSA-P.11-07 Testing method for measuring efficiency and energy consumption of gas-fired unit heaters | Thermal efficiency ≥ 80% at maximum input, and must be equipped with an intermittent ignition device and (a) a power-vented system; (b) an automated vent damper; or (c) an automated flue damper. | June 1, 2012 |
8 Room air conditioners | CAN/CSA-C368.1-M90 Performance Standard for Room Air Conditioners | Column 3 of Table 1 of CAN/ CSA-C368.1-M90 | June 1, 1995 |
Second column of Table 2 of CAN/CSA-368.1-M90 | August 31, 2004 |
8.1 Portable air conditioners with CSA C370-09 test configuration number 5 and a cooling capacity that does not exceed 10.55 kW (36,000 BTU/h) | CSA C370-09 Cooling performance of portable air conditioners | Spot Cooling Efficiency = 7.76 + 0.0164 × cooling capacity in BTU/h/1000 | June 1, 2012 |
9 Gas ranges with electric cord sets | | No standing pilot | June 1, 1995 |
10 Oil-fired water heaters with an input rating of 107 000 kJ/h or not more than 30.5 kW (0.75 U.S. gallons per hour) and a storage capacity of not more than 190 l | CAN/CSA-B211-M90 Seasonal Energy Utilization Efficiencies of Oil-Fired Water Heaters | Clause 7.1 of CAN/CSA-B211-M90 | June 1, 1995 |
CSA B211-00 Energy Efficiency of Oil-Fired Storage Tank Water Heaters | Clause 8 of CSA B211-00 | August 31, 2004 |
11 Electric induction motors that are polyphase, squirrel cage, single speed, NEMA/EEMAC (National Electrical Manufacturers Association/Electrical and Electronic Manufacturers Association of Canada) Design A or B from 1 to 200 hp inclusive, other than integral gear motors | CSA C390-93 Energy Efficiency Test Methods for Three-Phase Induction Motors | Table 2 of CSA C390-93 | June 1, 1995 |
11.1 Electric induction motors, other than integral gear motors, continuous duty, open or closed, polyphase, squirrel cage, single speed, EEMAC/NEMA design A or B type, two, four or six pole, that are at least one but not more than 200 hp (0.75 to 150 kW) 600 volts maximum, 50/60 or 60 Hz | CAN/CSA-C390-98 Energy Efficiency Test Methods for Three-Phase Induction Motors | Clause 4.10 and Tables 2 and 2A of CAN/CSA-C390-98 | August 31, 2004 |
11.2 Electric three-phase induction motors rated 0.746 kW at 1,800 rpm (or equivalent) and greater. | CSA C390-10 Test methods, marking requirements, and energy efficiency levels for three-phase induction motors | Clause 6.1 and Tables 2 and 4 of CSA C390-10 | June 1, 2012 |
12 Fluorescent lamp ballasts | CAN/CSA-C654-M91 Fluorescent Lamp Ballast Efficacy Measurements | Clause 4.1 of CAN/CSA-C654-M91 | June 1, 1995 |
Power factor = 90% and fifth column of clause 4.1 of CAN/CSA-C654-M91 as per General Instruction May 2001 | March 31, 2005 |
12.1 Replacement fluorescent lamp ballasts | CAN/CSA-C654-M91 Fluorescent Lamp Ballast Efficacy Measurements | Power factor = 90% and fifth column of clause 4.1 of CAN/CSA-C654-M91 as per General Instruction May 2001 | June 1, 2012 |
13 Ground or water source heat pumps that are unitary single package or split system matching assemblies rated at a capacity below 35 kW (120,000 BTU/h) and intended application in open or closed loop ground or water source systems | CAN/CSA-C446-94 Performance of Ground and Water Source Heat Pumps | Clause 5.1 of CAN/CSA-C446-94 | June 1, 1995 |
CAN/CSA-C446-94 Performance of Ground and Water Source Heat Pumps or CAN/CSA-C13256-1-01, Water-source heat pumps- Testing and rating for performance - Part I: Water-to-air and brine-to-air heat pumps | Clause 5.1 of CAN/CSA-C446-94 or clauses 3.8 and 3.9 of CAN/CSA-C13256-1-01 | August 31, 2004 |
14 Air conditioners and heat pumps that are air source, air sink, split-system, unitary devices intended for air conditioning and heating applications that are rated at a capacity not exceeding 19 kW (65,000 BTU/h) in either cooling or heating mode | CAN/CSA-C273.3-M91 Performance Standard for Split-System Central Air-Conditioners and Heat Pumps | Column 3 of Table 1 of CAN/ CSA-C273.3-M91 | June 1, 1995 |
CAN/CSA-C656-05 Performance standard for split-system and single-package central air conditioners and heat pumps | Clauses 7.2.2 and 7.3 and Columns 3 and 4 of Table 3 of CAN/CSA-C656-05, and Clause 7.2.1 and Columns 1 and 2 of Table 3 of CAN/CSA-C656-05 for all prescribed products not assigned minimum efficiencies in Column 3 or 4 of that table | June 1, 2012 |
14.1 Split-system central air conditioners that use single-phase electric current | CAN/CSA-C273.3-M91 Performance Standard for Split-System Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 10.0 | August 31, 2004 |
14.2 Split-system central air conditioners that use three-phase electric current | CAN/CSA-C273.3-M91 Performance Standard for Split-System Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 10.0 | August 31, 2004 |
14.3 Split-system heat pumps that use single-phase electric current | CAN/CSA-C273.3-M91 Performance Standard for Split-System Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 10.0 and heating seasonal performance factor (Region V) ≥ 5.9 | August 31, 2004 |
14.4 Split system heat pumps that use three-phase electric current | CAN/CSA-C273.3-M91 Performance Standard for Split-System Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 10.0 and heating seasonal performance factor (Region V) ≥ 5.9 | August 31, 2004 |
14.5 Single package central air conditioners that are through-the-wall | CAN/CSA-C656-05 Performance standard for split-system and single-package central air-conditioners and heat pumps | Seasonal energy efficiency ratio ≥ 12.0 | June 1, 2012 |
14.6 Single package heat pumps that are through-the-wall | CAN/CSA-C656-05 Performance standard for split-system and single-package central air-conditioners and heat pumps | Seasonal energy efficiency ratio ≥ 12.0 and heating seasonal performance factor (Region V) ≥ 6.4 | June 1, 2012 |
15 Water source heat pumps that are factory built single package or split system matching assemblies that are intended for installation in internal water loop systems, that do not exceed 40 kW (135,000 BTU/h) in cooling or heating capacity | CAN/CSA-C655-M91 Performance Standard for Internal Water-Loop Heat Pumps | Clause 5.2 of CAN/CSA-C655-M91 | June 1, 1995 |
CAN/CSA-C655-M91 Performance Standard for Internal Water-Loop Heat Pumps or CAN/CSA-C13256-1-01, Water-source heat pumps - Testing and rating for performance - Part I: Water-to-air and brine-to-air heat pumps | Clause 5.2 and Table 2 of CAN/ CSA-C655-M91, or clause 8A and Table 10A of CAN/CSA-C13256-1-01 | August 31, 2004 |
16 Air conditioners and heat pumps that are air source, air sink, single package, unitary devices intended for air conditioning and heating applications that are rated at capacity not exceeding 19 kW (65,000 BTU/h) | CAN/CSA-C656-M92 Performance Standard for Single Package Central Air-Conditioners and Heat Pumps | Clause 5.2 of CAN/CSA-C656-M92 | June 1, 1995 |
16.1 Single package vertical air conditioner rated at a capacity below 19 kW (65,000 BTU/h) | CAN/CSA-C746-06 Performance standard for rating large and single packaged vertical air conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2) of CAN/CSA-C746-06 | June 1, 2012 |
16.2 Single package vertical air conditioner rated at a capacity of not less than 19 kW (65,000 BTU/h) but below 40 kW (135,000 BTU/h) | CAN/CSA-C746-06 Performance standard for rating large and single packaged vertical air conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2) of CAN/CSA-C746-06 | June 1, 2012 |
16.3 Single package vertical air conditioner rated at a capacity of not less than 40 kW (135,000 BTU/h) | CAN/CSA-C746-06 Performance standard for rating large and single packaged vertical air conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2) of CAN/CSA-C746-06 | June 1, 2012 |
16.4 Single package vertical heat pump rated at a capacity below 19 kW (65,000 BTU/h) | CAN/CSA-C746-06 Performance standard for rating large and single packaged vertical air conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2) of CAN/CSA-C746-06 | June 1, 2012 |
16.5 Single package vertical heat pump rated at a capacity of not less than 19 kW (65,000 BTU/h) but below 40 kW (135,000 BTU/h) | CAN/CSA-C746-06 Performance standard for rating large and single packaged vertical air conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2) of CAN/CSA-C746-06 | June 1, 2012 |
16.6 Single package vertical heat pump rated at a capacity of not less than 40 kW (135,000 BTU/h) | CAN/CSA-C746-06 Performance standard for rating large and single packaged vertical air conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2) of CAN/CSA-C746-06 | June 1, 2012 |
17 Roadway lighting luminaires of cobra-head type using 50 to 400 W high pressure sodium lamps and small or medium prismatic glass, polycarbonate and acrylic refractors | CAN/CSA-C653-92 Performance Standard for Roadway Lighting Luminaires | Column 6 of Table 1 of CAN/ CSA-C653-92 | January 1, 1996 |
17.1 Cobra-head type luminaries using 70 to 400 W metal halide (MH) lamps | CAN/CSA-C653-08 Photometric performance of roadway lighting luminaries | Clause 4.6 and Table 1 of CAN/CSA-C653-08 | June 1, 2012 |
18 Gas-fired automatic storage type water heaters with storage tank volumes of 76 l to 380 l inclusive, for use with propane and natural gas with inputs less than 75,000 BTU/h | CGA /CAN1-4.1-M85 Gas-Fired Automatic Storage Type Water Heaters with Inputs less than 75,000 BTU/h | Clause 2.1.9 of CGA/ CAN1-4.1-M85 | June 1, 1995 |
CAN/CSA-P.3-98 Testing Method for Measuring Energy Consumption and Determining Efficiencies of Gas-Fired Storage Water Heaters | EF = 0.67-0.0005 V | August 31, 2004 |
CAN/CSA-P.3-04, Testing Method for Measuring Energy Consumption and Determining Efficiencies of Gas-Fired Storage Water Heaters (as revised in March 2006) | EF ≥ 0.70-0.0005 V | June 1, 2012 |
19 Commercial and industrial unitary air conditioners, heat pumps and condensing units intended for air conditioning and space heating applications that are rated at a capacity above 19 kW (65,000 BTU/h) and below 73 kW (250,000 BTU/h) | CAN/CSA-C746-93 Performance Standard for Rating Large Air Conditioners and Heat Pumps | Clause 6.2 of CAN/CSA-C746-93 | June 1, 1995 |
19.1 Factory-assembled commercial and industrial unitary air conditioners, heat pumps and air conditioning condensing units that are rated at a capacity of at least 19 kW (65,000 BTU/h) to 73 kW (250,000 BTU/h) and that are single or three phase, including all sizes of single packaged vertical air conditioners and heat pumps | CAN/CSA-C746-06 Performance standard for rating large and single packaged air-conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2) of CAN/CSA-C746-06 | June 1, 2012 |
20 Absorption or vapour compression refrigeration chillers intended for application in air-conditioning systems that are factory-built and equipped with centrifugal, rotary screw or positive displacement compressors with a cooling capacity of not more than 600 kW (20,000,000 BTU/h) | CSA C743-93 Performance Standard for Rating Packaged Water Chillers | Column 4 and Column 6 of Table 10 of CSA C743-93 | August 1, 1996 |
20.1 Factory-designed and fabricated vapour-compression chillers intended for application in air-conditioning systems for buildings that have a cooling capacity of less than 7 000 kW with water-cooled condensers and less than 700 kW with air-cooled condensers and absorption chillers with water-cooled condensers of up to 5 600 kW | CAN/CSA-C743-09 Performance standard for rating packaged water chillers | Clause 7 and Tables 9 and 10 of CAN/CSA-C743-09 | June 1, 2012 |
21 Oil-fired warm-air furnaces, other than furnaces for mobile homes and recreation vehicles, having an input rate of up to and not more than 66 kW (225,000 BTU/h) | CSA B212-93 Seasonal Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers | Clause 7.1 of CSA B212-93 | Sept. 1, 1995 |
CSA B212-00 Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers | Clause 7.1 of CSA B212-00 | August 31, 2004 |
22 Oil-fired central heating boilers intended for low pressure steam or hot water systems having an input rate of up to and not more than 88 kW (300,000 BTU/h) | CSA B212-93 Seasonal Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers | Clause 7.2 of CSA-B212-93 | Sept. 1, 1995 |
CSA B212-00 Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers | Clause 7.2 of CSA B212-00 | August 31, 2004 |
23 Self-contained gas burning central heating boilers that are intended for low pressure steam or hot water systems having an input rate of up to and not more than 88 kW (300,000 BTU/h) | CGA 4.9-1969 Gas-Fired Steam and Hot Water Boilers | When measured in accordance with CGA P.2-1991, Hot water systems: Annual fuel utilization efficiency ≥ 80% Low pressure steam systems: Annual fuel utilization efficiency ≥ 75% | June 1, 1995 |
CAN/CSA-P.2-07 Testing method for measuring the annual fuel utilization efficiency of residential gas-fired furnaces and boilers | No continuous pilot; Hot water systems: Annual fuel utilization efficiency ≥ 82% No continuous pilot; Low pressure steam systems: Annual fuel utilization efficiency ≥ 80% No continuous pilot; automatic water temperature adjustment; Hot water systems: Annual fuel utilization efficiency ≥ 82% | June 1, 2012 June 1, 2012 September 1, 2012 |
24 Dehumidifiers that are factory-assembled electric dehumidifiers that are mechanically refrigerated and that have a water removal capacity not exceeding 30 l/d (63.4 U.S. pints per day) | CAN/CSA-C749-94 Performance of Dehumidifiers | Clause 4.2 of CAN/CSA-C749-94 | August 31, 2004 |
24.1 Household factory-made dehumidifiers with a daily water-removal capacity of up to 87.5 l | CAN/CSA-C749-07 Performance of dehumidifiers | Clauses 6.2 and 6.3 and Tables 1 and 2 of CAN/CSA-C749-07 | June 1, 2012 |
25 General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power requirement in excess of 35 W | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 75 lm/ W and average colour rendering index ≥ 69 | August 31, 2004 |
25.1 General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power requirement no greater than 35 W | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 75 lm/ W and average colour rendering index ≥ 45 | August 31, 2004 |
25.11 General service fluorescent lamps that are rapid-start, straight-shaped fluorescent lamps with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power requirement of 25 W but not exceeding 32 W for indoor applications | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 88 lm/ W and average colour rendering index ≥ 80 | June 1, 2012 |
25.12 General service fluorescent lamps that are instant-start, straight-shaped with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power requirement of 25 W but not exceeding 32 W for indoor applications | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 90 lm/ W and average colour rendering index ≥ 80 | June 1, 2012 |
25.2 General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a recessed double contact base, a nominal power requirement in excess of 100 W and a nominal current of 0.8 A | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 80 lm/ W and average colour rendering index ≥ 69 | August 31, 2004 |
25.3 General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a recessed double contact base, a nominal power requirement no greater than 100 W and a nominal current of 0.8 A | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 80 lm/ W and average colour rendering index ≥ 45 | August 31, 2004 |
25.4 General service fluorescent lamps that are rapid-start U-shaped fluorescent lamps with a nominal overall length of 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power requirement in excess of 35 W | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 68 lm/ W and average colour rendering index ≥ 69 | August 31, 2004 |
25.5 General service fluorescent lamps that are rapid-start U-shaped fluorescent lamps with a nominal overall length of not less than 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power requirement no greater than 35 W | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 64 lm/ W and average colour rendering index ≥ 45 | August 31, 2004 |
25.6 General service fluorescent lamps that are instant-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power requirement in excess of 65 W | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 80 lm/ W and average colour rendering index ≥ 69 | August 31, 2004 |
25.7 General service fluorescent lamps that are instant-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power requirement no greater than 65 W | CAN/CSA-C819-95 Performance of General Service Fluorescent Lamps | Average lamp efficacy ≥ 80 lm/ W and average colour rendering index ≥ 45 | August 31, 2004 |
26 Incandescent reflector lamps | CSA C862-01 Performance of Incandescent Reflector Lamps | Tables 1 and 2 of CSA C862-01 | August 31, 2004 |
CSA C862-09 Performance of incandescent reflector lamps | Clause 7.2 and Table 1 of CSA C862-09 | June 1, 2012 |
26.1 Torchieres | CAN/CSA-C867.1-08 Performance of torchieres | Clause 4.1, 4.2, 5.1 and 5.2, including Table 1, of CAN/CSA-C867.1-08 | June 1, 2012 |
27 Ice-makers | CSA C742-98 Performance of Automatic Ice-Makers and Ice Storage Bins | Table 2 of CSA C742-98 | August 31, 2004 |
27.1 Factory-made ice storage bins and self-contained or split-system automatic ice-makers that use air- or water-cooled condensers that do not exceed 1 814 kg/d of cube, flake, crushed or fragmented ice | CAN/CSA-C742-08 Energy performance of automatic icemakers and ice storage bins | Clause 5.4.3 and Table 4 of CAN/CSA-C742-08 Clause 5.4.1 and Table 2 of CAN/CSA-C742-08 for all ice-makers not included in Table 4 Clause 5.4.2 and Table 3 of CAN/CSA-C742-08 for all ice storage bins | June 1, 2012 |
28 Integrated over/under washer-dryers | CSA C360-98 Energy Performance, Water Consumption, and Capacity of Automatic Household Clothes Washers for the clothes washer component, and CAN/CSA-C361-92 Test Method for Measuring Energy Consumption and Drum Volume of Electrically Heated Household Tumble-Type Clothes Dryers for the clothes dryer component | Clause 7.5 of CSA C360-98 for the clothes washer component, and Table 8.1 of CAN/CSA-C361-92 for the clothes dryer component | August 31, 2004 |
CAN/CSA-C360-03 Energy Performance, Water Consumption, and Capacity of Household Clothes Washers (as reaffirmed in 2009) for the clothes washer component, and CAN/CSA-C361-92 Test Method for Measuring Energy Consumption and Drum Volume of Electrically Heated Household Tumble-Type Clothes Dryers for the clothes dryer component | Clause 8.5.3 and Table 11 of CAN/CSA-C360-03 (as reaffirmed in 2009) for the clothes washer component, and Table 8.1 of CAN/CSA-C361-92 for the clothes dryer component | June 1, 2012 |
29 Packaged terminal air conditioners | ARI 310/380-2004/CSA C744-04 Standard for Packaged Terminal Air Conditioners and Heat Pumps | Table 2 of ARI 310/380-2004/ CSA C744-04 | August 31, 2004 |
30 Packaged terminal heat pumps | ARI 310/380-2004/CSA C744-04 Standard for Packaged Terminal Air Conditioners and Heat Pumps | Table 2 of ARI 310/380-2004/ CSA C744-93 | August 31, 2004 |
31 Single package central air conditioners that use single-phase electric current and that do not exceed 19 kW (65,000 BTU/h) in cooling or heating capacity | CAN/CSA-C656-M92 Performance Standard for Single Package Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 9.7 | August 31, 2004 |
CAN/CSA-C656-05 Performance standard for split-system and single-package of central air conditioners and heat pumps | Clauses 7.2.2 and 7.3 and Columns 3 and 4 of Table 3 of CAN/CSA-C656-05, and Clause 7.2.1 and Columns 1 and 2 of Table 3 of CAN/CSA-C656-05 for all prescribed products not assigned minimum efficiencies in Column 3 or 4 of that table | June 1, 2012 |
32 Single package central air conditioners that use three-phase electric current and that do not exceed 19 kW (65,000 BTU/h) in cooling or heating capacity | CAN/CSA-C656-M92 Performance Standard for Single Package Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 9.7 | August 31, 2004 |
CAN/CSA-C656-05 Performance standard for split-system and single-package central air conditioners and heat pumps | Clauses 7.2.2 and 7.3 and Columns 3 and 4 of Table 3 of CAN/CSA-C656-05, and Clause 7.2.1 and Columns 1 and 2 of Table 3 of CAN/CSA-C656-05 for all prescribed products not assigned minimum efficiencies in Column 3 or 4 of that table | June 1, 2012 |
33 Single package heat pumps that use single-phase electric current and that do not exceed 19 kW (65,000 BTU/h) in heating or cooling capacity | CAN/CSA-C656-M92 Performance Standard for Single Package Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 9.7 and heating seasonal performance factor (Region V) ≥ 5.7 | August 31, 2004 |
CAN/CSA-C656-05 Performance standard for split-system and single-package central air conditioners and heat pumps | Clauses 7.2.2 and 7.3 and Columns 3 and 4 of Table 3 of CAN/CSA-C656-05, and Clause 7.2.1 and Columns 1 and 2 of Table 3 of CAN/CSA-C656-05 for all prescribed products not assigned minimum efficiencies in Column 3 or 4 of that table | June 1, 2012 |
34 Single package heat pumps that use three-phase electric current and that do not exceed 19 kW (65,000 BTU/h) in heating or cooling capacity | CAN/CSA-C656-M92 Performance Standard for Single Package Central Air-Conditioners and Heat Pumps | Seasonal energy efficiency ratio ≥ 9.7 and heating seasonal performance factor (Region V) ≥ 5.7 | August 31, 2004 |
CAN/CSA-C656-05 Performance standard for split-system and single-package central air conditioners and heat pumps | Clause 7.2.2 and 7.3 and Columns 3 and 4 of Table 3 of CAN/CSA-C656-05, and Clause 7.2.1 and Columns 1 and 2 of Table 3 of CAN/CSA-C656-05 for all prescribed products not assigned minimum efficiencies in Column 3 or 4 of that table | June 1, 2012 |
35 Commercial or industrial unitary air conditioner with a cooling capacity of not less than 19 kW (65,000 BTU/h) but not more than 73 kW (250,000 BTU/h) | CSA C746-98 Performance Standard for Rating Large Air Conditioners and Heat Pumps | Table 6 of CSA C746-98 | August 31, 2004 |
35.1 Commercial or industrial unitary air conditioners, heat pumps and air conditioning condensing units that have a cooling capacity of at least 19 kW (65,000 BTU) and that are single or three phase, including all single package vertical air conditioners or heat pumps | CAN/CSA-C746-06 Performance standard for rating large and single packaged vertical air conditioners and heat pumps | Clause 7.2 and Table 8 (Level 2 or, if no Level 2 is prescribed, Level 1) of CAN/CSA-C746-06 | June 1, 2012 |
36 Power transformers as described in CSA standard CAN/CSA 802.3-01 rated from 501 to 10,000 kV•A | CAN/CSA-C802.3-01 Maximum Losses for Power Transformers | Clauses 4.1.2 and 4.2 and Tables 1, 2 and 3 of CAN/CSA-C802.3-01 | June 30, 2005 |
36.1 Liquid-filled distribution transformers, that are single-phase and three-phase, 60 Hz, rated at 10 to 833 kV•A for single-phase and 15 to 3 000 kV•A for three-phase, insulation class 34.5 kV and less | CSA C802.1-00 Minimum Efficiency Values for Liquid-Filled Distribution Transformers | Clause 7 and Table 1 of CSA C802.1-00 | August 31, 2004 |
CAN/CSA-C802.1-00 Minimum Efficiency Values for Liquid-Filled Distribution Transformers (as reaffirmed in 2011) | Clause 7 and Table 1 of CAN/CSA-C802.1-00 (as reaffirmed in 2011) | June 1, 2012 |
36.2 Dry-type transformers that are single-phase and three-phase, self-contained units or components of larger assemblies, 60 Hz, ANN, rated at 15 to 833 kV•A for single-phase and at 15 to 7 500 kV•A for three-phase | CSA C802.2-00 Minimum Efficiency Values for Dry-Type Transformers | Clauses 7 and 8 and Table 1 of CSA C802.2-00 | December 31, 2004 |
CAN/CSA-C802.2-06 Minimum efficiency values for dry-type transformers | Clauses 7 and 8 and Table 1 of CAN/CSA-C802.2-06 | June 1, 2012 |
37 Self-ballasted compact fluorescent lamps and ballasted adapters designed for use with a replaceable fluorescent lamp in an E26 medium screwbase lampholder | CAN/CSA-C861-95 Performance of Compact Fluorescent Lamps and Ballasted Adapters | Clause 6.6 and Tables 1A and 1B, and clause 6.8 and Table 2 of CAN/CSA-C861-95 | August 31, 2004 |
37.1 Self-ballasted compact fluorescent lamps and ballasted adapters designed for use with a replaceable fluorescent lamp in an E26 or larger screwbase | CAN/CSA-C861-06 Performance of self-ballasted compact fluorescent lamps and ballasted adapters | Clause 7.7 and Table 3, Clause 7.9 and Clause 7.11.2 and Table 4 of CAN/CSA-C861-06 | June 1, 2012 |
38 Dusk to dawn luminaires or area security lights, for use in non-hazardous locations that are intended for installation outdoors on branch circuits of 600 volts or less, using either a 175 to 400 W mercury vapour, 50 to 400 W high pressure sodium (HPS), or 18 to 55 W low pressure sodium (LPS) lamp, complete with photoelectric controller | CAN/CSA-C239-02 Performance Standard for Dusk to Dawn Luminaires | Table 1 of CAN/CSA-C239-02 | June 30, 2005 |
39 Vending machines, self-contained, that cool or heat the product to be vended | CAN/CSA-C804-96 Energy Performance of Vending Machines | Clause 4.1 and Table 1 of CAN/ CSA-C804-96 | August 31, 2004 |
CSA C804-09 Energy performance of vending machines | Clause 5.1 and Table 1 of CSA-C804-09 | June 1, 2012 |
40 Commercial refrigerators, with glass or solid doors, that are reach-in type wine coolers, milk or beverage coolers or under counter work tables | CSA C827-98 Energy Performance Standard for Food Service Refrigerators and Freezers | Tables 1 and 2 of CSA C827-98 | August 31, 2004 |
High efficiency column of Tables 1 and 2 of CSA C827-98 | June 1, 2012 |
40.1 Self-contained commercial refrigerator with opaque cabinet doors or opaque cabinet drawers | AHRI 1200-2008 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | Edaily = 0.00353 V + 2.04 | June 1, 2012 |
40.2 Self-contained commercial refrigerator with opaque cabinet doors or transparent cabinet drawers not for pull-down temperature application | AHRI 1200-2008 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | Edaily = 0.00424 V + 3.34 | June 1, 2012 |
40.3 Self-contained commercial refrigerator with opaque cabinet doors or transparent cabinet drawers for pull-down temperature application | AHRI 1200-2008 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | Edaily = 0.00445 V + 3.51 | June 1, 2012 |
41 Commercial freezers, with glass or solid doors, that are reach-in type, ice cream cabinets or worktop table/undercounter | CSA C827-98 Energy Performance Standard for Food Service Refrigerators and Freezers | Tables 3 and 4 of CSA C827-98 | August 31, 2004 |
High efficiency column of Tables 3 and 4 of CSA C827-98 | June 1, 2012 |
41.1 Self-contained commercial freezer with opaque cabinet doors or opaque cabinet drawers | AHRI 1200-2008 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | Edaily = 0.01413 V + 1.38 | June 1, 2012 |
41.2 Self-contained commercial freezer with opaque cabinet doors or transparent cabinet drawers not for pull-down temperature application | AHRI 1200-2008 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | Edaily = 0.02649 V + 4.10 | June 1, 2012 |
42 Refrigerator-freezers, solid door, reach-in vertical split type | CSA C827-98 Energy Performance Standard for Food Service Refrigerators and Freezers | Table 5 of CSA C827-98 | August 31, 2004 |
High efficiency column of Table 5 of CSA C827-98 | June 1, 2012 |
42.1 Self-contained commercial refrigerator-freezer with opaque cabinet doors or transparent cabinet drawers not for pull-down temperature application | AHRI 1200-2008 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | Edaily = the greater of (0.00953 V - 0.71) or 0.70 | June 1, 2012 |
43 Ceiling fans, pendant and hugger style, 250 volts or less, intended for residential, commercial or industrial installations | CSA C814-96 Energy Performance of Ceiling Fans | Clause 4.3 of CSA C814-96 | August 31, 2004 |
CAN/CSA-C814-10 Energy performance of ceiling fans | Clause 5.1 and Table 2; Clause 5.2 and Table 5; and Clause 5.3 and Table 7 of CAN/CSA-C814-10 | June 1, 2012 |
44 Drinking water coolers | CSA C815-99 Energy Performance of Drinking-Water Coolers | Clause 4.2 and Tables 1 and 2 of CSA C815-99 | August 31, 2004 |
CAN/CSA-C815-09 Energy performance of drinking water coolers | Clause 5.2 and Table 1 or 2, as applicable, of CAN/CSA-C815-09 | June 1, 2012 |
Clause 5.3 and Table 3 (maximum standby energy for high-efficiency bottle-type) of CAN/CSA-C815-09 | June 1, 2012 |
45 Highmast luminaires, using high pressure sodium lamps, for use along streets, roadways, highways, expressways and at intersections and interchanges | CAN/CSA-C811-98 Performance of Highmast Luminaires for Roadway Lighting | Clause 4.5 and Tables 1, 2 and 3 of CAN/CSA-C811-98 | August 31, 2004 |
46 Exit signs | CAN/CSA-C860-01 Performance of Internally Lighted Exit Signs | Maximum wattage = 5 × (number of legends), for Type 1 and Type 2 exit signs and 5 × (number of legends) + 5, for Type 3 exit signs | August 31, 2004 |
CAN/CSA-C860-07 Performance of internally lighted exit signs | Clause 10.3.1.1 and Table 4 of CAN/CSA-860-07 | June 1, 2012 |
47 Compact and standard size gas-fired clothes dryers for domestic applications | CGA P.5-M97 Testing Method for Measuring Per-Cycle Energy Consumption and Energy Factor of Domestic Gas Clothes Dryers | Not less that the Minimum Energy Factor for Appendix B of CGA P.5-M97 | August 31, 2004 |
CSA P.5-09 Test method for measuring per-cycle energy consumption, energy factor, and low power mode energy consumption of residential gas clothes dryers | Not less that the Minimum Energy Factor (1.21 kg per kWh) from Annex A of CSA P.5-09 | June 1, 2012 |
48 Swimming pool heaters of all inputs, gas-fired, convection and other than convection (forced circulation) types | CGA P.6-1993 Testing method for measuring Thermal and Operating Efficiencies of Gas-Fired Pool Heaters | Thermal efficiency ≥ 78% | August 31, 2004 |
48.1 Gas-fired swimming pool heaters | CSA P.6-09 Test method for measuring thermal efficiency of gas-fired pool heaters | Thermal efficiency ≥ 78% | June 1, 2012 |
49 Ballasts for high-intensity discharge (HID) and low pressure sodium (LPS) lamps | CAN/CSA-C863-04 Energy efficiency of high-intensity discharge (HID) and low pressure sodium (LPS) lamp ballasts | Ballast efficiency ≥ 85% | June 1, 2012 |
50 Heat and energy recovery ventilators | CAN/CSA-C439-09 Standard laboratory methods of test for rating the performance of heat/energy-recovery ventilators | Heat-recovery efficiency ≥ 55% | June 1, 2012 |
51 Centrifugal pumps that require driver rated output of 373W (0.5 hp) nominal up to and including 7.46 kW (10 hp) nominal | CAN/CSA-C820-02 Energy Efficiency Test Methods for Small Pumps | Clauses 4.2 and 5 and Table 1 of C820-02 | June 1, 2012 |
52 Thermostats used for line-voltage (120-240 volts) switching of a controlled resistive heating load, including wall-mounted, built-in (up to 1 500 W), and two component thermostats | CAN/CSA-C828-06 Performance requirements for thermostats used with individual room electric space heating devices | Clause 4.3.2 of CAN/CSA-C828-06, Maximum Droop = 1.5 ºC; Clause 4.33 of CAN/CSA-C828-06, Maximum Differential = 0.5 ºC; and Clause 4.3.4 of CAN/CSA-C828-06, Set Point Precision within 0.5 ºC | June 1, 2012 |
53 Traffic and pedestrian signalization modules | Institute for Transportation Engineers (ITE), Vehicle Traffic Control Signal Heads (VTCSH), 2005, Part 2 | Maximum wattage of 15 W per module | June 1, 2012 |
54 Solid-fuel-burning heating appliances | CAN/CSA-B415.1-00 Performance Testing of Solid-Fuel-Burning Heating Appliances | Clause 4.2 of CAN/CSA-B415.1-00 | June 1, 2012 |
55 Toilets | CSA B45.1-08 Ceramic plumbing fixtures | Maximum water consumption of less than 6.0 l per flush | June 1, 2012 |
56 Urinals | CSA B45.1-08 Ceramic plumbing Fixtures | Maximum water consumption of 0.5 l per flush | June 1, 2012 |