Enabling Act
0
Full text
NEW BRUNSWICK
REGULATION 2014-96
under the
Boiler and Pressure Vessel Act
(O.C. 2014-286)
Filed August 12, 2014
1
The enacting clause of New Brunswick Regulation 84-174 under the Boiler and Pressure Vessel Act is repealed and the following is substituted:
Under section 40 of the
Boiler and Pressure Vessel Act
, the Lieutenant-Governor in Council makes the following Regulation:
2
The heading “AGE LIMIT FOR RIVETED HIGH PRESSURE BOILERS (LAP SEAM)” preceding section 108 of the Regulation is repealed.
3
Section 108 of the Regulation is repealed.
4
The heading “LIQUEFIED PETROLEUM GAS PRESSURE VESSELS” preceding section 109 of the Regulation is repealed.
5
Section 109 of the Regulation is repealed.
6
Subsection 111(3) of the Regulation is amended by striking out “shall hold an ASME Certificate of Authorization,”.
7
Section 114 of the Regulation is amended by striking out “shall obtain a certificate of inspection in respect of the boiler or pressure vessel and”.
8
The heading “SPACE FOR REGISTRATION STAMP” preceding section 304 of the Regulation is repealed.
9
Section 304 of the Regulation is repealed.
10
The heading “FORMS SUPPLIED BY DEPARTMENT” preceding section 305 of the Regulation is repealed.
11
Section 305 of the Regulation is repealed.
12
Subsection 307(1) of the Regulation is amended by striking out “and boilers and pressure vessels may be manufactured in any number to such registered designs” and substituting
“to allow boilers and pressure vessels to be manufactured in any number in accordance with the registered designs”
.
13
Section 308 of the Regulation is amended by striking out “and no further construction using the design shall be commenced”.
14
Section 309 of the Regulation is amended by striking out “and shall revise the design to meet the approval of the Chief Inspector”.
15
Section 311 of the Regulation is repealed and the following is substituted:
REJECTED DESIGNS
311
If a design does not meet with the approval of the Chief Inspector or of a design review organization approved by the Chief Inspector, a report setting out the reasons why the design does not meet with the approval of the Chief Inspector or of the design review organization shall be sent by the Chief Inspector or the design review organization to the manufacturer.
16
Section 317 of the Regulation is amended by striking out “listing each item to be registered and indicating that such items” and substituting
“indicating that all the items listed in the catalogue”
.
17
Subsection 319(1) of the Regulation is amended by striking out “, except condensers, which may be located exterior to the building”.
18
Section 320 of the Regulation is amended by striking out “, which shall be paid”.
19
Section 503 of the Regulation is amended
(
a
)
by repealing subsection (3);
(
b
)
by repealing subsection (4).
20
Subsection 512(2) of the Regulation is repealed.
21
Section 602 of the Regulation is amended
(
a
)
in subsection (2) by striking out “fabrication, construction, installation and operation” and substituting
“fabrication and installation”
;
(
b
)
by repealing subsection (3).
22
This Regulation comes into force on October 1, 2014.
Copy
Select this element
Select parent element
Unselect all
Copy to Drafting
Copy to LAW
Copy to Clipboard
To copy : Ctrl+C
0
Advanced search (includes point-in-time)
Consolidated Acts and Regulations
Acts
by title
by chapter
by department
Regulations
by regulation number
Annual Acts and Regulations
Acts
by year
Regulations
by year
Access Rules of Court
by rule number
Repealed Legislation (2011 onward)
Acts
by title
Selections
Show
Selections in current document
All selections in the collection
Selected elements
Delete all selections
Show selections
Cyberlex
Version 2.2.6.0